Furnace Condensate Drain Pipe Size

Hvac Russell King M E Condensate Drain Drain Hvac

Hvac Russell King M E Condensate Drain Drain Hvac

Outside Ac Unit Diagram Condensate Handling Air Conditioning Heat Pump Condensate Handling Heat Pump Heat Exchanger Refrigeration And Air Conditioning

Outside Ac Unit Diagram Condensate Handling Air Conditioning Heat Pump Condensate Handling Heat Pump Heat Exchanger Refrigeration And Air Conditioning

Three Ways To Check Duct Sizing In The Field Hvac Design Hvac Duct Hvac

Three Ways To Check Duct Sizing In The Field Hvac Design Hvac Duct Hvac

Hvac Russell King M E Condensate Drain Drain Hvac

Hvac Russell King M E Condensate Drain Drain Hvac

4904d1154714355 Condensation Drain Vent Furnacventrs Gif 640 608 Refrigeration And Air Conditioning Heating Hvac Duct Work

4904d1154714355 Condensation Drain Vent Furnacventrs Gif 640 608 Refrigeration And Air Conditioning Heating Hvac Duct Work

Home Air Ventilation Stunning Hvac Duct Sizes Duct Sizing Chart Throughout Flex Duct Sizing Chart24391 Duct Work Hvac Duct Piping And Instrumentation Diagram

Home Air Ventilation Stunning Hvac Duct Sizes Duct Sizing Chart Throughout Flex Duct Sizing Chart24391 Duct Work Hvac Duct Piping And Instrumentation Diagram

Home Air Ventilation Stunning Hvac Duct Sizes Duct Sizing Chart Throughout Flex Duct Sizing Chart24391 Duct Work Hvac Duct Piping And Instrumentation Diagram

Condensate waste and drain line size shall be not less than 3 4 in.

Furnace condensate drain pipe size.

Where the drainpipes from more than one unit are manifolded together for condensate drainage the pipe or tubing shall be sized in accordance with table 307 2 2. Plastic with a separate drain installed under. Its job is to efficiently funnel condensation away from your hvac unit. Drain shall have a minimum slope of 1 8 ft verify pipe sizing and discharge requirements with local authorities and codes.

An auxiliary condensate drain pan at least 1 5 deep and at least 3 larger than the length width of the appliance beneath which it is placed using corrosion resistant material of adequate thickness 0 7mm galvanized metal or 1 6mm non metallic e g. Pipe size shall not be smaller than drain pan outlet. 3 4 is sufficient for up to 20 tons according to the imc unless the drain outlet size is larger than 3 4. This process creates condensate or moisture from the furnace s heat exchanger.

I removed the duct tape. The condensate pipe drains the moisture into a floor drain or household drain pipe. It connects directly to the hvac unit and leads outdoors often through an exterior wall. Drain s 2015 imc 307 2 2 requires that an air conditioning condensate drain inside diameter should not be smaller than in ch and should not be smaller than the drain pan outlet diameter.

In a couple cases it looks like there is a separate 1 2 or 3 4 pvc pipe coming out of the wall. Enter the condensate line which essentially functions as a drain line. Depth of trap must exceed by one pipe diameter the total static pressure of fan. Minimum size below grade and below ground floor shall be 2 1 2.

Three quarters of an inch is sufficient for up to 20 tons according to the imc unless the drain outlet size is larger than in ch use t able 307 2 2 for condensate pipe sizing. Internal diameter and shall not decrease in size from the drain pan connection to the place of condensate disposal. Can a condensate line coming off of the furnace to the floor drain have it s vent pipe covered with duct tape on the top. After the first stage the hot exhaust gasses are cycled through a second combustion stage resulting in exhaust with very little heat.

I have been trying to get an answer from the furnace company as to why this was done. In another it looks like there is a small drain pipe inside the flue pipe leading out. This is what a service tech did to the vent. Condensate lines are typically made of plastic commonly pvc or sometimes metal although plastic is prefered.

An auxiliary drain pan with separate drain. Where the drain pipes from more than one unit are manifolded together for condensate drainage the pipe or tubing shall be sized in accordance with table 307 2 2 i interpret this to mean for more than one unit the total capacity should be used to size the collective condensate drain per table 307 2 2.

Condensate Drain Codes Best Practices Hvac School Condensate Drain Hvac Drain

Condensate Drain Codes Best Practices Hvac School Condensate Drain Hvac Drain

Cfm Chart Hvac Design Duct Work Hvac Ductwork

Cfm Chart Hvac Design Duct Work Hvac Ductwork

Pin On Hvac Tech

Pin On Hvac Tech

Flex Duct Sizing Chart Unique Hvac Duct Hvac Duct Size Chart Pertaining To Flex Duct Sizing Chart24391 Flex Duct Dust Collection Hvac Duct

Flex Duct Sizing Chart Unique Hvac Duct Hvac Duct Size Chart Pertaining To Flex Duct Sizing Chart24391 Flex Duct Dust Collection Hvac Duct

Source : pinterest.com